API PLAN 23

The water cooler was designed according to ASME Sec. VIII Div. 1, API 682 is specially designed and tested to be used in high pressure. Built with a retractable coil, drain and vent make easier maintenance.

The ATC-585 coolant is based on the properties of minimum flow of 5 ppm and minimum at 50°C. The standard welding requirements meet the ASME IX norms. Every cooler tested according to ASME, 1.5 times design pressure. The carbon steel shell is cleaned and painted for the chemical ambient attack. Please, specify suitable material, connection, and options for your application. Viton is used as a standard material for flange gaskets.

Options &Accessories :
  • Pressure Indicator Dial Size 100 mm
  • Relief valve
  • Flow indicator
  • Flow transmitter
  • Hand pump
  • Temperature Transmitter
  • Thermowell
  • Magnetic separator
  • 100% Radiography test & Reports
  • NACE materials
  • Ferrite Test (F number or F %)
  • Hardness Test.
Configuration
Material of Construction SS316/L , As per client req.
Welding Book (WPS, Weld map) ASME Sec. IX / EN 15614-1
Construction Code- Vessel ASME Sec. VIII Div. 1
Construction Code- Piping ASME B31.3
Provisional Certification as applicable ASME U Stamp API 682 Ed. 4th
Documentation
Pressure Part Certificates EN 10204 Type 3.1 / 3.2
Structure Part Certificates EN 10204 Type 3.1 / 2.1 / 2.2
Orientation & Sizes Dimension Reports
NDE Testing Reports VT,LPT, RT, PMI, Ferrite etc
Leak test Reports Hydro / Pneumatic Test Report
Surface Cleaning Certificate Pickling passivation
Surface Coating Certificate Painting Report