Portable units enable manual refilling of a seal reservoir or barrier fluid circuit while the system is pressurized and in operation.
Material used for this is mostly stainless steel 316/L, 304/L grade. ATC can provide the same as per customer required grade.
Water fill up test is performed at ambient temperature to detect leakage in welds.
As per client’s test requirement, ATC can fulfill all testing requirements either through NABL laboratory or concerned test service providers.
Configuration | |
Material of Construction | SS316/L , As per client req. |
---|---|
Welding Book (WPS, Weld map) | ASME Sec. IX / EN 15614 |
Construction Code- Piping | ASME B31.3 |
Certification as applicable | Nil |
Documentation | |
Wetted Part Certificates | EN 10204 Type 3.1 / 3.2 |
---|---|
Non wet Part Certificates | EN 10204 Type 3.1 / 2.1 / 2.2 |
Orientation & Sizes | Dimension Reports |
NDE Testing Reports | VT,LPT, RT, PMI, Ferrite etc |
Leak test Reports | Water fill Test Report |
Surface Cleaning Certificate | Pickling passivation |
Surface Coating Certificate | Painting Report |