MOBILE TROLLY

Portable units enable manual refilling of a seal reservoir or barrier fluid circuit while the system is pressurized and in operation.

Material used for this is mostly stainless steel 316/L, 304/L grade. ATC can provide the same as per customer required grade.

Water fill up test is performed at ambient temperature to detect leakage in welds.

As per client’s test requirement, ATC can fulfill all testing requirements either through NABL laboratory or concerned test service providers.

Configuration
Material of Construction SS316/L , As per client req.
Welding Book (WPS, Weld map) ASME Sec. IX / EN 15614
Construction Code- Piping ASME B31.3
Certification as applicable Nil
Documentation
Wetted Part Certificates EN 10204 Type 3.1 / 3.2
Non wet Part Certificates EN 10204 Type 3.1 / 2.1 / 2.2
Orientation & Sizes Dimension Reports
NDE Testing Reports VT,LPT, RT, PMI, Ferrite etc
Leak test Reports Water fill Test Report
Surface Cleaning Certificate Pickling passivation
Surface Coating Certificate Painting Report